Installing The Product; Electric Connections; Power Supply Connections - Key Automation 14A Instrucciones Y Advertencias

Central modular para uno o dos motores de 24 vcc
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
EN

4 - INSTALLING THE PRODUCT

4.1 - Electrical connections
WARNING - Before making the connections, ensure that the control unit is not powered up
M2
M1
M1
M2
ECLIPSE
COM
LED
FLASH SEN
22
PO24 POWER MODULE
M2
SBS
GND
PO24 CONNECTIONS
LS1
Limit switch 1 input (only for SUN)
LS2
Limit switch 2 input (only for SUN)
Limit switch / encoder power supply positive common
V+
(12 Vdc 50 mA MAX)
ENC
Encoder S signal input
NEG
Encoder power supply negative
M-
Motor output
Earth
M+
Motor output

POWER SUPPLY CONNECTIONS

L
Power supply 230 Vac 50-60 Hz
Earth
N
Power supply neutral 230 Vac 50-60 Hz
M
M1
1
2
1 2
3 4
12/24
GND
12/24
COM OUT
_
_
AC/DC
AC/DC
NC
1
TX
RX
PH1
GND
_
2
1 2
3 4
12/24
GND
12/24
COM OUT
_
AC/DC
AC/DC
NC
TX
RX
PH2
TRANSFORMER
T2A
N
L

Publicidad

Tabla de contenido
loading

Tabla de contenido