All flammable materials must be removed from
under the appliance or protected by at least a 6
cm concrete slab.
Flammable walls bordering the appliance must
be protected by at least a 10 cm stone wall and
5 cm insulation.
Protect non-flammable walls bordering the
appliance with at least 2.5 cm insulation to
avoid cracking.
Protect a flammable floor from heat radiation
and falling ash by means of a fireproof pro-
tective plate. See the appendix "Distance from
combustible material".
Keep enough distance between the appliance
and combustible materials such as furniture.
Ensure sufficient ventilation around flammable
materials such as a mantelpiece. See
appendix "Distance from combustible mater-
ial".
Carpets and rugs must be at least 80 cm away
from the fire.
Do not place any flammable materials within
50  cm of any convection outlets.
10

Product description

1
2
3
4
5
9
10
1. Convection air connection
2. Door
3. Fitting frame
4. Outside decorative frame
5. Bottom of the fire compartment
6. Air slide
7. Inner plates
8. Door latch
9. Flue gas connection
10. Outside air connection
11. Magnets for the decorative frame
Features of the appliance
The appliance is supplied with a connecting kit for
the outside air supply.
The appliance is not suitable for continuous use.
The insert fireplace has an integrated convection
system. This means that when installing the appli-
ance it is not necessary for a separate convection
Subject to change because of technical improvements
6