Floors And Walls; Product Description - Dovre 2020 Instrucciones De Instalacion Y Uso

Ocultar thumbs Ver también para 2020:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 142

Floors and walls

The floor on which the appliance is placed must have
sufficient bearing capacity. For the weight of the
appliance, see the appendix "Technical data".
There may not be any electrical wires in the
floor below the appliance and in the walls
around it.
All flammable materials must be removed from
under the appliance or protected by at least a 6
cm concrete slab.
Flammable walls bordering the appliance must
be protected by at least a 10 cm stone wall and
5 cm insulation.
Protect non-flammable walls bordering the
appliance with at least 2.5 cm insulation to
avoid cracking.
Protect a flammable floor from heat radiation
and falling ash by means of a fireproof
protective plate. See the appendix "Distance
from combustible material".
Keep enough distance between the appliance
and combustible materials such as furniture.
Ensure sufficient ventilation around flammable
materials such as a mantelpiece. See
appendix "Distance from combustible
material".
Carpets and rugs must be at least 80 cm away
from the fire.
Do not place any flammable materials within
50 cm of any convection outlets.
6
All manuals and user guides at all-guides.com

Product description

1. Secondary air slide
2. Door
3. Outside decorative frame
4. Riddling rod
5. Primary air slide
6. Latch
7. Fire basket
8. Fireproof inner plates
Features of the appliance
The appliance is supplied with a separate handle,
the so-called 'cold hand', for opening the door.
The appliance is supplied with a second separate
handle, the so-called 'cold hand', for removing the
ashpan; see next figure.
Subject to change because of technical improvements

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

220022102220250025102520

Tabla de contenido