Exploded View Of Scale - Health O Meter 752KL Manual De Operación

Ocultar thumbs Ver también para 752KL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATOR ACTION
Turn the scale on. While "START" is displayed on the LCD (for 3 seconds)
press the ZERO-KG/LB-KG/LB-ZERO keys one at a time on the keypad.
Press "ENTER"
Press "ENTER" to calibrate with 200 lb. This can be changed if desired.
To change the calibration weight, press the BMI key. Then, use the arrow keys to change the value of the flashing digit.
Use the BMI key to advance to the next digit, and again use the arrow keys to change the digit to the desired value.
Repeat until you have entered the desired calibration weight. Press "ENTER"
The calibration weight must be no less than 100 lb (45 kg) and no more than 300 lb (135 kg).
Clear the weight from the platform and press "ENTER"
Wait without touching or shaking the scale until the zero calibration
process is finished
Load the platform with the required weight and press "ENTER"
Wait without touching or shaking the scale until the zero calibration process is finished.
Note:
If the calibration is done in lb, the factor value you should have is
0.9000 – 1.000 If the calibration is done in kg, the factor value should be
0.4000 – 0.4250. If the factor value is different repeat the calibration procedure.
Press ENTER
Remove weight from the platform
Wait until the scale resumes normal operation

Exploded View of Scale

6
DISPLAY
"CAL" will appear on the LCD
Enter load weight "Load/200.0"
"CLEAR"
Zero Calibration "------------"
Weight calibration "Put XXX.X"
Weight calibration "------------"
Calibration "Factor X.XXXX"
"DONE"/"CLEAR"/XXX
Rebooting, please wait
"0.0"

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

599kl597kl

Tabla de contenido