Wiring of the standard device
I
Tip!
Parameter setting and configuration can be carried out using the
L−force »Engineer«. For this purpose the Online Help and the Software Manual
for the standard device will guide you.
System bus CAN on board
Terminal X1
9400SSP000X1
)
Note!
The X1 connection is not available in the "StateLine" design.
24 V supply
Terminal X2
9400SSP000X2
Terminal data
Flexible
With wire end ferrule
58
Labelling
Description
Pin 2
CAN−LOW
Pin 3
CAN−GND
Pin 7
CAN−HIGH
(Housing)
CAN−Shield
Labelling
Description
GE
GND external supply
24E
24 V external supply via a safely separated power supply
unit (SELV/PELV) (only required for mains−independent supply of the
control electronics)
SB
State bus in/out (reference GE)
Conductor cross−section
2
[mm
]
0.2 ... 2.5
l
Tightening torque
[AWG]
[Nm]
24 ... 12
Spring terminal
[lb−in]
EDK94ASH24 DE/EN/FR/ES/IT 5.0