Astralpool LAGHETTO PLAYA Serie Manual De Uso Y Mantenimento página 46

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

PLAYA - USE AND MAINTENANCE
SET BUTTON (BLOWER)
• Turns on and off the air massage.
• If pressed for 3 seconds changes the parameter shown on the display (Water
temperature – clock)
Display current
water temperature
SETTING PARAMETERS FOR THE GENERAL USER
• Turn off the unit by pressing for 3 seconds the ON-OFF button.
• Wait 1 minute until the arrest of the filtration pump.
• Pressing the LIGHT button for 3 seconds to access to the following parameters:
PARAMETER
water temperature
U0
setting ° C
hysteresis water
U1
temperature
duration of ignition
U2
Blower- air massage
timeout duration
U3
ignition light
inhibition time of the
U4
piezoelectric blower
button
46
DESCRIPTION
it sets the desired
water temperature
it sets the hysteresis
of the desired water
temperature
it sets the duration in
minutes of air massage
it sets the length of
light ignition when
it is turned on with
the control unit or
piezoelectric button
it sets the time in
which the piezoelectric
blower button is
inhibited; only after
this time it can be
pressed again
Clock
display
FUNCTION
NOT PRESENT IN THIS
NOT PRESENT IN THIS
(maximum value)
DEFAULT
VERSION
VERSION
20
min
00
hours
(Set duration)
00
sec