PLAYA - USE AND MAINTENANCE
ACTIONS TAKEN
DISPLAYED
FROM THE
MESSAGE
CONTROL SYSTEM
if turned on,
FLC
heater is
switched off
a LED flashes in
the lower right
on the display
when the heater
is in operation.
If the LED is
off, despite the
no alarm, but
set temperature
the pool warms
is higher than
slightly
water, it means
that we are in
a transitional
phase of pre-
clogging and
the heater was
turned off
a LED flashes
no alarm, but
in the lower
the pool warms
right on the
slightly
display
a LED flashes
no alarm, but
in the lower
the pool warms
right on the
slightly
display
ITEM THAT
POSSIBLE
GENERATED THE
CAUSES
ALARM
the flow switch
detects the
flow switch
flow even with
blocked or
the filtration
defective
pump turned
off
the flow
switch is in an
semi-clogged
intermediate
filter
stage on / off
lack of
isotherm
cover, setting
the filtration
--
cycles (the
heater turns on
only when the
filter pump is
running)
the protection
fuse output of
the heater is
interrupted,
--
the protection
tab of the
heater is
broken
RECOVERY MODE
Replacement of the
switch, the alarm
is reset by pressing
the on-off button
Clean the filter
use the isotherm
cover, the filter
pump has to
operate 24 hours
replace fuse,
check heater
protection tab,
replace heater