PARAMETER
inhibition time
U5
piezoelectric light
button
ANTI STAGNATION FUNCTION (AUTOMATIC)
It is an automatic function that activates the blower for 30 seconds and the filter
pump for 3 hours when the latter has been off for more than 48 hours
The following table summarizes all the signal codes of alarms, with their
descriptions, that the control unit is capable of signaling.
ACTIONS TAKEN
DISPLAYED
BY THE CONTROL
MESSAGE
no alarm, but
--
the controller's
display does not
turn on
no alarm, but
--
a shock is
perceived when
entering the
water
3. HEATER AND BUBBLES VERSION
IMPORTANT: In this version of PLAYA is mounted a 230V electric
heater from 2.000W able to raise to 15° C the water temperature
reached by the version without heater (data valid with a isothermal
coverage installed).
DESCRIPTION
it sets the time in
which the piezoelectric
button is inhibited
after finishing the
cycle set in U2
parameter; only after
this time can be
pressed again

ALARM SIGNALS

ITEM THAT
GENERATED
SYSTEM
THE ALARM
--
--
FUNCTION
NOT PRESENT IN THIS
POSSIBLE CAUSES
lack of power.
Fuse of the
controller
interrupted
inadequate
grounding
DEFAULT
VERSION
RECOVERY MODE
check the power
supply line.
Check the fuse
of the control
unit
check the
grounded
installation by a
technician