8. Once the led has lighted on, stop unscrewing. After 10 seconds, the valve will start a
backwash routine.
9. Open the return to pool valve and check the green led lights off. Check the valve
completes the full cycle (backwash + rinse) and returns to filter position at the end.
10. Assemble again the rubber cap. Now the valve is ready to work.
Note: If there is a change on the installation that may cause different flow or pressure
conditions, the pressure switch may have to be tuned again.
15/12/2010
Fig. 26.- Pressure switch with rubber protection.
Página 18 de 19
Installation Manual
BASIC Automatic
Multiport Valve