Direct Panels (Without Display); Access Control - Fermax ADS Manual De Programación

Ocultar thumbs Ver también para ADS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

VDS - B
VDS - B
VDS - B
VDS - B
US2
US2
US2
US2
VDS - B
VDS - BUS2
VDS - B
VDS - B
VDS - BUS2
VDS - B
US2
US2
US2
US2

1.- DIRECT PANELS (without Display)

1.1.- ACCESS CONTROL

Every panels with keypad, includes a basic access control function allowing users open
the door by entering a 4 digits code.
In order to use this function it must have been previously enabled and once in use there is
no way to disable the function (this means that there will always be a door opening code,
known by users or not).
Activation sequence
1.-Power down the system and make a short between "BS" and "-" terminals of the
amplifier (or press the indoor opening pushbutton if installed).
2.-Power up the system and remove the short. There is only a single minute to enable
the opening code.
3.-Dial programming code 3 1 4 1 (this code cannot be modified) and dial the desired
code (four digit code) to open the door and press
Changing the code
Previous code must be known in order to change it (when unknown, the activation sequence
must be repeated to store the new one).
The sequence:
1.- dial the programming code: 3 1 4 1
2.- dial the opening code to change
3.- dial the new opening code and press
REMARKS:
Dial 'a' to erase or restart the dialling sequence
Ensure the short between "BS" and "-" has been removed before closing the outdoor
panel
Once activated the opening code this function cannot be disabled. This means that
always there will be an opening code, known or not by the users of the system.
Pag 22
.
.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

VdsBus2

Tabla de contenido