420010280905 Max 15 - 20 - 30
EN
NOZZLE
gph
spry
1,50
60°
1,65
60°
1,75
60°
2,00
60°
2,25
60°
2,50
60°
2,75
60°
3,00
60°
3,50
60°
4,00
60°
1,75
60°
2,00
60°
2,25
60°
2,50
60°
2,75
60°
3,00
60°
3,50
60°
4,00
60°
4,50
60°
2,25
60°
2,50
60°
3,00
60°
3,50
60°
4,00
60°
4,50
60°
5,00
60°
5,50
60°
6,00
60°
6,50
60°
SUNTEC
ASV 47 A
3
6
P
SUNTEC
SUNTEC
1
VERIFY:
- That piping system is perfectly sealed.
- That the use of hoses is avoided whenever is possible (use copper pipes preferably).
- That depression is not greater than 0,45 bar, to avoid pump's cavitation.
- That check valve is suitably designed for the duty.
The pump pressure is set at a value of 12 bar during the testing of burners. Before starting the burner, bleed
the air in the pump through the gauge port. Fill the piping with light-oil to facilitate the pump priming. Start
the burner and check the pump feeding pressure. In case the pump priming does not take place during the
first prepurging, with a consequent, subsequent lock-out of the burner, rearm the burner's lock-out to restart,
by pushing the button on the control box. If, after a successful pump priming, the burner locks-out after the

ADJUSTMENT DATA

PUMP
OUTPUT
bar
kg/h
12
6,2
12
7,0
12
7,6
12
8,3
12
9,3
12
10,4
12
11,5
12
12,5
12
14,9
11
16,0
12
7,6
12
8,3
12
9,3
12
10,4
12
11,5
12
12,5
12
14,9
12
16,7
12
19,1
12
9,3
12
10,4
12
12,5
12
14,9
12
16,7
12
19,1
12
21,8
12
23,6
12
25
11
27
NOZZLE : DANFOSS H÷S 80°÷60°; DELAVAN W 60°; STEINEN S 60°

PRIMING AND ADJUSTMENT OF OIL PUMP

DANFOSS
BFP 21 R3
7
4
5
5
V
P
-
2
FIRING HEAD SETTING AIR DAMPER ADJUSTMENT
Pos.
0
1
2
2,5
3
3,5
4
4,5
5
5
0
1
2
2,5
3
3,5
4,0
4,5
5
0
0,5
1,5
2,0
2,5
3
3,5
4
4,5
5
1 - INLET
2 - RETURN
3 - BLEED AND PRESSURE GAUGE PORT
4 - VACUUM GAUGE PORT
5 - PRESSURE ADJUSTMENT
6
6 - TO NOZZLE
7 - CARTRIDGE FILTER
P
3
+
4
V
2
1
10
Pos.
1,5
2,0
2,5
3,0
3,2
3,5
4
4,5
4,5
5
1,5
1,7
2
2,8
3
3,6
4,1
4,3
5
1,5
2
2,2
2,5
3
3,3
3,8
4
4,5
5