Adjustment Data; Nozzle Cleaning And Replacement - Ecoflam MAX P 35 AB Manual De Instrucciones

Ocultar thumbs Ver también para MAX P 35 AB:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
A
To adjust LOW air flow, turn the screw B as required. To reduce output, turn screw clockwise, to increase it turn screw
counterclockwise.
To adjust HI air flow, turn the screw A as required. To reduce output, turn screw counterclockwise, to increase it turn
screw clockwise.
Output
kW
1°st
2°st
1°st
244
432
20,6
221
370
18,7
206
310
17,4
168
255
14,2
320
549
27
265
486
22,4
258
390
21,8
196
296
16,6
UGELLO : DANFOSS H÷S 80°÷60°; DELAVAN W 60°; STEINEN S 60°
Use only the suitable box wrench provided for this opera-
tion to remove the nozzle, taking care to not damage the
electrodes. Fit the new nozzle with the same care.
Note: Always check the position of electrodes after having
replaced the nozzle (see illustration). A wrong position
could cause ignition troubles.
FIRING HEAD / AIR SETTING
1
2
B
VERSION AB
2
D
E
T
A
L I

ADJUSTMENT DATA

Output
kg/h
Nozzle
2°st
1°st
2°st
36,5
5
4
31,2
4,5
3
26,2
4
2
21,5
4
2
46,3
6
5
41
5,5
4,5
33
5
3,5
25
4
2

NOZZLE CLEANING AND REPLACEMENT

Air
Pump
Setting
bar
1°st
2°st
11,5
1,8
4
12
1,8
4
14
1,7
4
10
1,5
4
11
1,8
4
11,5
1,8
4
10
1,7
4
12
1,5
4
4 mm
17
420010334402 Max P 35 / 45 AB
1
D
E
T
A
L I
Head
Setting
4
3
2
1
4
3
2
1
6 mm
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Max p 45 ab

Tabla de contenido