6 Commissioning
CAUTION

Risk of injury

Physical injury caused by the start of the wire.
• Keep process-side drive away from the body.
7 Close and lock the cover (2).
6.5 Changing the drive rollers
1
Pressure lever
2
Pressure rockers (2 pcs.)
Fig. 9
Changing the drive rollers
NOTICE
• Always replace or reverse the wire feed rollers in pairs.
• Observe the groove geometry and the wire diameter.
• The wire feed rollers should be changed whenever the wire type or the wire diameter are changed or the wire feed
rollers are worn out.
If required, the wire must be cut through and then fed in again.
 6.4 Feeding in the wire on page EN-11
1 Open the cover on the M-Drive.
2 Fold the pressure lever (1) outward.
3 Swing the pressure rockers (2) open using the pressure rollers (3).
4 Unscrew the retaining screws (6) from the wire feed rollers (5).
5 Replace and re-attach the wire feed rollers (5).
6 Screw on the retaining screws (6) and use the pressure rollers (3) to close the pressure rockers (2).
7 Fold the pressure lever (1) back to upper position.
EN - 12
1
6
3
pressure rollers (2 pcs.)
4
full-floating axle (2 pcs.)
M-Drive
2
5
wire feed rollers (2 pcs.)
6
retaining screws (2 pcs.)
BAL.0393.0 • 2018-08-14
3
4
5