ADJUSTING THE LIMIT STOPS - IXENGO S 24 V

Adjust the limit stops by correctly positioning the end of travel magnets on the 24 V motor drive unit.
Important: For the 230 V motor drive unit, refer to the instructions on the FX 230 electronic controller and adjust
the time that the motor operates.

Adjusting the FC1 closing limit stop

[1] Close the gate section.
[2] Slacken screws I and J on the closing limit stop.
[3] Move the limit stop so that the distance between screw J and the gate section mounting bracket axis is some 376 mm.
[4] Close the gate.
[5] If the gate section stops too soon in relation to the desired position, slightly move the limit stop towards the end of the
drive rod.
[6] If the gate section hits the limit stop on the ground when closing, and the motor drive unit reverses direction, then
move the limit stop slightly towards the motor drive unit's body.
[7] After correctly defi ning the limit stop's position, tighten down screws I and J.
Adjusting the FC2 opening limit stop
[1] Open the gate section.
[2] Slacken screws K and L on the opening limit stop.
[3] Move the limit stop so that the distance between screw L and the gate section mounting bracket axis is some 376 mm.
[4] Open the gate.
[5] If the gate section stops too soon in relation to the desired position, slightly move the limit stop towards the motor
drive unit's body.
[6] If the gate section hits the limit stop on the ground when opening, and the motor drive unit reverses direction, then
move the limit stop slightly towards the end of the drive rod.
[7] After correctly defi ning the limit stop's position, tighten down screws K and L.
Note: When programming the electronic controller, always anticipate when the limit stops will take action. To properly
press against the limit stops on the ground, the motor drive unit continues its movement for 1 or 2 cm (some 100 ms).