If dimension B is excessive:
•
Use adjustable mounts (9014609 or 9014610) that allow setting the following four or eight values of Z (in cases where
you need to reduce or increase the value of Z):
P1: Z = 77 mm
P5: Z = 150 mm
P2: Z = 90 mm
P6: Z = 165 mm
P3: Z = 110 mm
P7: Z = 190 mm
P4: Z = 150 mm
P8: Z = 200 mm
Adjustable mount installation position
Left
Right
•
Or move the gate hinges so as to reduce distance
•
Attach the mounting bracket
Drill and bolt the mounting bracket to the post.
Use a type of mounting that suits the post.
Mount direction
Left
Right
Note: Use the large circlips to attach the mounting bracket P.
Example
When the desired opening angle is 90°:
•
Measure dimension
X = 30 mm.
•
Calculate dimension
B = X + Z = 30 + 110 = 140 mm.
•
Apply dimension
B = 140 to the table and use a dimension A = 140 for a 90° opening.
Fitting the gate section
mounting bracket
Important: On the gate section, measure dimension C
(993 mm), the length between the two mounting bracket
centres. Mark the mounting axis for the gate section
mounting bracket.
[1] Release the motor drive unit E. Extend the drive rod till
the end of its travel.
[2] Temporarily fi t the motor drive unit on its mount P.
[3] Fit the gate section mounting bracket F onto the drive
rod E with its pivot pin G.
[4] Check that the motor drive unit E is horizontally aligned
using a spirit level.
[5] Attach the gate section mounting bracket F.
6
P9: Z = 215 mm
P10: Z = 225 mm
P1
P2
P3
P4
B (refer to "Specifi c Installations").
P.
P5
P11: Z = 235 mm
P6
P12: Z = 250 mm
P7
P8
P9
P10
P11
P12
Z
P
P
Copyright © 2008 Somfy SAS. All rights reserved.
Z
F
G
E