OPERATING TEST

Opening the gate by hand

If necessary, the motor drive unit is provided with a release key so that the gate section can be moved by hand.
[1] After lifting the lock cover, insert the release key and turn it clockwise by 90°.
[2] Push the gate section by hand to open the gate.
[3] Turn the release key in the opposite direction to return to motor driven operation.
[4] Refi t the lock cover.

Checking operation

Before starting up the motor drive unit:
Check that all components are solidly mounted
Check all safety mechanisms for correct operation
Check the emergency operation control
Check that the electronic controller is operating correctly.

What do I do if the motor drive unit fails?

Use a suitable instrument to check for the presence of voltage on the ends of the motor reduction gear unit after an
opening or closing operation.
If the drive rod does not turn in the right direction, reverse the electrical operating connections on the motor reduction
gear unit.
If the gate reverses direction after opening or closing, this means that the limit stops have not been correctly set. Refer
to the section called "Adjusting the limit stops" to refi ne the position of the limit stops.

SPECIFICATIONS

Power supply
Rotation speed
Power consumption
Current consumption
Push and pull torque
Useful travel
Drive rod speed
Obstacle detection (impact reaction)
Limit stops
Manual operation
Nbr. of operations per 24 hours
Maximum gate section length
Maximum gate section weight
Ambient conditions
Protection level
Lubrication
Capacitor
Copyright © 2008 Somfy SAS. All rights reserved.
24 V version
24 V DC
3800 rpm
40 W
1.5 A
2000 N
280 mm
14 mm/s
Built-in torque limiter
Built-in, magnetic and adjustable
By unlocking key
60 operations
1800 mm
250 kg
-20°C to +60°C
IP44
Greased for life
-
230 V version
230 V AC
2800 rpm
210 W
0.8 A
2000 N
280 mm
12 mm/s
Electronic clutch on the control panel
-
By unlocking key
60 operations
1800 mm
250 kg
-20°C to +60°C
IP44
Greased for life
6.3 μF