How to Start
1.
Set the On/Off switch to "On" and allow tank pressure to build. Motor will stop
when tank pressure reaches "cut-out" pressure.
2.
Turn regulator knob clockwise to increase pressure and stop when desired
pressure is reached.
Risk of unsafe operation. If any unusual noise or vibration is
noticed, stop the compressor immediately and have it checked by a trained
service technician.
The compressor is ready for use.
CUSTOMER RESPONSIBILITIES
Check Safety Valve
Drain Tank
Remove tank from service
For more information, call our Customer Care Center at 1-(888)-848-5175
1-
power is on. When performing maintenance, you may be exposed to voltage
sources, compressed air, or moving parts. Personal injuries can occur. Before
performing any maintenance or repair, disconnect power source from the
compressor and bleed off all air pressure.
NOTE: See Operation section for the location of controls.
TO CHECk SAFETY VALVE
Risk of Bursting. If the safety valve does not work properly,
over-pressurization may occur, causing air tank rupture or an explosion.
Risk from Flying Objects. Always wear certified safety
equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields.
Before starting compressor, pull the ring on the safety valve to make sure that the
safety valve operates freely. If the valve is stuck or does not operate smoothly, it
must be replaced with the same type of valve.
TO DRAIN TANk
Risk of Unsafe Operation. Air tanks contain high pressure air.
Keep face and other body parts away from outlet of drain. Use ANSI Z87.1
eye protection (CAN/CSA Z94.3) when draining as debris can be kicked up
into face.
Risk from noise. Use ear protection [(ANSI S12.6 (S3.19) hear-
ing protection] as air flow noise is loud when draining.
NOTE: All compressed air systems generate condensate that accumulates in
any drain point (e.g., tanks, filter, aftercoolers, dryers). This condensate contains
lubricating oil and/or substances which may be regulated and must be disposed of in
accordance with local, state, and federal laws and regulations.
1.
Set the On/Off switch to "Off".
MAINTENANCE
Risk of unsafe operation. Unit cycles automatically when
Before
each use
x
12 - ENG
Daily
See tank
or after
warning
each
label
use
x