Troubleshooting - Porter Cable CFFN251N-P Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Risk of Unsafe Operation. Unit cycles automatically when
power is on. When servicing, you may be exposed to voltage sources, com-
pressed air, or moving parts. Before servicing unit unplug or disconnect
electrical supply to the air compressor, bleed tank of pressure, and allow the
air compressor to cool.
PROBLEM
Excessive tank pressure
- safety valve pops off.
Air leaks at fittings.
Air leaks in air tank
or at air tank welds.
Air leaks between
head and valve plate.
Air leak from
safety valve.
Knocking Noise.

TROUBLESHOOTING

CAUSE
Pressure switch does
not shut off motor when
compressor reaches
"cut-out" pressure.
Pressure switch "cut-
out" too high.
Tube fittings are not
tight enough.
Defective air tank.
Leaking seal.
Possible defect in
safety valve.
Possible defect in
safety valve.
16 - ENG
CORRECTION
Move On/Off lever to
the "Off" position, if
the outfit does not shut
off contact a Trained
Service Technician.
Contact a Trained
Service Technician.
Tighten fittings where air
can be heard escaping.
Check fittings with
soapy water solution.
Do Not Overtighten.
Air tank must be
replaced. Do not
repair the leak.
Risk
bursting. Do not drill
into, weld or otherwise
modify air tank or it will
weaken. The tank can
rupture or explode.
Contact a Trained
Service Technician.
Operate safety valve
manually by pulling on
ring. If valve still leaks,
it should be replaced.
Operate safety valve
manually by pulling on
ring. If valve still leaks,
it should be replaced.

Publicidad

Tabla de contenido
loading

Tabla de contenido