Press the pedal for changing the brushes
downward beyond its resistance.
Drive the appliance in reverse till the disk
brush is free.
Remove the disk brush and place the
new disk brush in front of the appliance.
Drive the appliance forward over the disk
brush.
Press the pedal for driving out the run-
ning gear and lock it to the left. The
brush will lock into the brush drive.
Set the advance speed.
Replace pump hose
Empty the dirty and fresh water tank.
Remove the detergent bottle from the
detergent holder.
Loosen the tank fastening screw and tilt
the tank upward.
The metering pump is located behind the
batteries.
1 Covering lid
2 Cover
3 Hose switch
4 Pump hose
5 Rotor
Remove covering lid.
Remove cover.
18
English
Remove the hose holder with the pump
hose (turn manually to remove the rotor
manually).
Replace pump hose.
Metering pump and appliance are brou-
ght into operational state by performing
the same steps in the reverse direction.
Maintenance contract
To ensure a reliable operation of the ap-
pliance maintenance contracts can be con-
cluded with the competent Windsor sales
office.
Frost protection
In case of danger of frost:
Empty the fresh and dirty water reser-
voirs.
Store the appliance in a frost-protected
room.
Troubleshooting
Danger
Risk of injury. Turn the program selection
switch to "OFF" and disconnect the mains
plug before performing any works on the ap-
pliance. Also turn the key switch to "0" and
press the emergency stop switch.
Drain and dispose of the dirty water and
the residual fresh water.
In case of faults that cannot be remedied
using the table below please contact the cu-
stomer service.
Note
If the display shows interruptions, first set
the program selection switch to OFF or dri-
ving and switch off the key switch (if availa-
ble). Wait for 15 seconds. Turn on the
appliance again. If the display still shows a
fault, then rectify the fault according to the
following table or call Customer Service.