8. INSTALL WALL EXTENSION (
AWWPD Series
Wall extension must be installed before the hood (see instructions packed with wall extension).

9. INSTALL HOOD

• Although not recommended, if blowers need to be removed, reinstall them using
10-32 locknuts included in parts bag (maximum torque of 20 lb.).
• Hold the hood until it is completely secured to the wood mounting strip.
Insert the house wiring in the hood through the wire clamp (previously installed in step 6) and tighten
the wire clamp to secure the wiring.
Rest the back cavity of the hood on
the wood mounting strip.
Attach 10" round duct to adapter.
Secure the hood to wood mounting
strip using 4 no. 10 x 2'' hex head
screws (for 36'' width hood) or
6 screws (for 42' , ' 48'' and 60'' width
hoods) at locations shown at right.
Drill two 3/16'' diameter holes into
the wall for wall anchors through the
existing holes in the lower back of
the hood at locations shown at right.
Then, install both wall anchors with
both no. 8 x 5/8'' screws and both
washers provided.
10. INSTALL DECORATIVE FLUE (
AEWPD Series
Refer to the instructions included with the optional decorative flue.

11. CONNECT WIRING

Risk of electric shock. Electrical wiring must be done by qualified personnel in
accordance with all applicable codes and standards. Before connecting wires,
switch power off at service panel and lock service disconnecting means to prevent
power to be switched on accidentally.
W
ATERPROOF WIRE CONNECTORS INSTRUCTIONS
1. Strip wires 3/8'' .
2. Align frayed strands or conductors.
3. Do not pre-twist. Place stripped wires together with ends even, but lead smaller stranded wires
slightly ahead of larger solid or stranded wire.
4. Twist connector onto wires pushing firmly until hand-tight. DO NOT over torque.
5. When inserting wires into connectors, some sealant may leak out. Wipe off excess sealant in and
around conductors. DO NOT REUSE.
OPTIONAL
CAUTION
HD0463
OPTIONAL
WARNING
!
: