Broan NuTone 2730 Manual De Instrucciones página 3

Sistema de ventilación de tiro
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PREPARATION
CHANgINg BLOWER DISCHARgE (Optional)
The blower is shipped with its discharge facing DOWN. Follow
these steps ONLY if:
the position of the blower discharge needs to be moved so duct-
work does not interfere with floor joists, plumbing or wiring below.
it is necessary to rotate the blower discharge to the RIGHT or LEFT.
Place the unit on its back on a table or work surface.
DOWN DISCHARgE - MOVINg BLOWER LEFT OR RIgHT
NUTS
CLAMP
CHANNEL
1. Loosen the 4 nuts and 2 clamp channels.
2. Slide blower to desired position.
3. Use supplied cover plate to close open space (if any).
4. Tighten wing nuts to secure top of blower and use sheet metal
screws through bottom flange to secure bottom of blower.
LEFT OR RIgHT DISCHARgE
NUT
CLAMP
CHANNEL
1. Remove the 4 nuts and 2 clamp channels.
2. Carefully lift blower and disconnect motor plug if necessary.
Reposition blower and RECONNECT MOTOR PLUG.
3. Use supplied cover plate to close open space (if any).
4. Replace clamp channels and use nuts to secure the blower
in its new position.
5. Use sheet metal screws through bottom flange to secure bot-
tom of blower.
SHEET
BLOWER
METAL
SCREW
BOTTOM
FLANGE
BLOWER
MOTOR
PLUG
COVER PLATE
CUT COUNTERTOP OPENINg
1. Lay out and cut the cooktop cut-out far enough FORWARD
so downdraft will fit behind it.
2. Set cooktop in place and slide it as far forward as possible.
Center and square it with edges of countertop.
3. Place the plastic template against the back flange of the cook-
top and center it. Trace around template to mark the downdraft
opening.
4. Remove cooktop from countertop.
5. Cut downdraft opening. Be careful not to chip edges of coun-
tertop.
MOUNT THE UNIT
LEVELING BRACKET -
FLANGE FACING OUT
SHEET
LEVELING BRACKET -
METAL
FLANGE FACING IN
SCREW
1. Set downdraft into opening. Extend leveling brackets to floor
of cabinet so downdraft sits straight. (Note: Leveling brackets
can be removed and re-attached in other positions. Bottom
flange may have to face inward in tight cabinet installations.)
2. Secure the downdraft to the countertop as follows: Hold the
downdraft against the back of countertop cut-out and tightening
the 2 mounting screws (one on each end of unit) on underside
of countertop. Use a wood shim between screw and underside
of granite countertops.
3. Screw leveling brackets to bottom of cabinet. Tighten screws
3
holding leveling bracket to unit on each side.
MOUNTING SCREWS

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Nutone 2736 eclipse

Tabla de contenido