CONNECTING THE EXTERNAL INJECTION
If the DOSATRON has already been used, please imperatively refer to chap-
ter PRECAUTIONS.
Fig. 11
ADJUSTING THE INJECTION RATE (with pressure off)
FOR ADJUSTABLE MODELS
IMPORTANT !
Use no tools
ADJUSTMENT MUST BE MADE
WHEN THERE IS NO PRESSURE IN
THE DOSATRON
- Turn off the water supply and allow
the
pressure to drop to zero.
- Unscrew the blocking ring (Fig. 12-B).
- Screw or unscrew the adjusting nut
(Fig. 13-D) so as to bring the top of
the nut into line with the desired
injection rate.
- Tighten the blocking ring (Fig. 12-B).
Model in the drawing : D 200 RE
©
DOSATRON INTERNATIONAL / 42
D
B
Fig. 12
Fig. 13
INTERNATIONAL CONVERSIONS
Principle : Setting at 1%
1/100 = 1 part of concentrate for 100 parts of
water.
Ex. : Setting at 2%
2/100 = 2 parts of concentrate for 100 parts of
water.
Ratio
1/50.
CHANGING SEALS IN THE INJECTION ASSEMBLY (with pressure off)
Frequency : Once per year.
IMPORTANT ! Use no tool or
metallic utensils
ADVICE: Before dismantling any
part of the injection assembly it is
advisable to operate the DOSA-
TRON, injecting clean water so as to
rinse through the injection system.
In this way, risks of contact with
concentrated solutions in the injec-
tion assembly are minimized.
During any such intervention, wear
protective eyewear and gloves !
METHOD OF REMOVING SEAL
Fig. 14 : Between finger and thumb,
pinch the component and the seal ;
push towards one side to deform the
seal.
Fig. 15 : Increase the deformation
to grip the part of the seal thus
exposed and pull it out of its groove.
©
DOSATRON INTERNATIONAL / 43
Clean the seal seating without any
tools.
Refitting is done by hand.
It is very important that the seal is
not twisted once in place as this
would impair its efficiency.
Fig. 14