6. MMA——MMA function.
Ⅲ-Operations:
1. 1. 1. 1. MMA parameters adjustment
MMA parameters adjustment
MMA parameters adjustment
MMA parameters adjustment
Adjust the 'welding mode selection switch' to MMA function. In MMA mode, only three parameters (welding current,
hot start, arc force) can be adjusted.
MMA parameters adjustment: Turn on the welder, the welding current can be adjusted directly; If adjust the selection
knob, the welding current LED (L4) is twinkling; It means the welding current can be adjusted. If the adjustment is
completed, confirm the parameter by pressing the 'selection knob' or the system will confirm the parameter
automatically after 3 seconds.
Other parameters such as arc force adjustment: press the'selection knob';Adjust the'selection knob'and select the
arc force LED(L13 is on); Press the'selection knob'again, the arc force LED(L13) is twinkling; It means the arc force
can be adjusted. If the adjustment is completed, press the'selection knob'and confirm the parameter; Or the system
will confirm the parameter automatically after 3 seconds. Operation flow as follows:
Step one: 'Welding mode selection switch' selects MMA mode, press the 'selection knob ';
Press the
'selection
knob'
Step two: Adjust the'selection knob'and select the arc force LED(L13 is on); Press the'selection knob'again, the arc
force LED(L13) is twinkling; It means the arc force can be adjusted..
Adjust the 'selection knob' and
select the arc force LED (L13 is
on); Press the 'selection knob'
again, the arc force LED (L13)
is twinkling; It means the arc
force value can be adjusted
Step three: If the adjustment is completed, press the'selection knob'and confirm the parameter; Or the system will
confirm the parameter automatically after 3 seconds.
If the adjustment is completed,
press the'selection knob'and
confirm the parameter; Or the
system will confirm the parameter
automatically after 3 seconds.
transcurridos 3 segundos.
2. 2. 2. 2. TIG parameters adjustment
TIG parameters adjustment
TIG parameters adjustment
TIG parameters adjustment
Adjust 'welding mode selection switch' to TIG mode. If in TIG 4T mode and the output pulse function is turned on,
all parameters (L1~L11) of TIG can be adjusted. If in TIG 2T mode and the output pulse function is turned on, the
start current and crater current is 5A; If the pulse function is closed, the parameter of base current(L5), pulse
frequency(L6) and pulse width(L7) can not be adjusted.
TIG parameters adjustment: The welding current (L4) can be adjusted directly when the welder is tune on. Adjust the
'selection knob', the welding current LED (L4) is twinkling; It means the welding current can be adjusted. If the
adjustment is completed, confirm the parameter by pressing the 'selection knob' or the system will confirm the
parameter automatically after 3 seconds.
Other parameters adjustment: Take 'pre flow time' for an example. Press the 'selection knob'; Adjust the'selection
knob'and select the pre flow time LED (L1 is on); Press the 'selection knob' again, the pre flow time LED (L1) is
twinkling; It means the pre flow time can be adjusted. If the adjustment is completed, confirm the parameter by
pressing the 'selection knob'; or the system will confirm the parameter automatically after 3 seconds. Operation flow
as follows:
Step one: 'Welding mode selection switch' select TIG 4T or 2T. Press the 'selection knob';
SMART 200 TIG PULSE
Welding mode
selection switch
select MMA
24