3.3. Welding Operation
3.3.1 Argon Arc Welding Operation
TIG long welding(4T):
I( A)
Welding current (peak
current) setting value
Base current setting
value
Press and hold the
welding gun switch
0
Introduction
0:Press and hold the gun switch, Electromagnetic gas valve is turned on. The shielding gas starts to flow;
0~t1:
t1: Striking success, adjustment range of start current: 5~160A(200A);
t2:Loosen the gun switch, the output current slopes up from start current; if the output pulse function is
turned on, the output current is pulsed;
t2~t3: Output current slopes up to the setting current value; adjustment range of up slope time 0~5.0S ;
t3~t4:Welding process. During this period, the gun switch is loosen;
Note: If the output pulse function is turned on, the output current is pulsed. If the output pulse function is
turned off, the output current is DC current;
t4:
Repress down the gun switch, the output current slopes down to crater current; if the output pulse
function is turned on, the slope down current is pulsed;
t4~t5:Down slope time, adjustment rang of down slope time: 0~5.0S;
t5~t6:Crater current holds time; adjustment range of crater current: 5~160A (200A);
t6: Loosen the gun switch, stop arc, and keep on argon flowing;
t6~t7:Post flow time, adjustment range of post flow time: 3.0~10.0S;
t7: Electromagnetic valve is closed and stop argon flowing. Welding is finished.
TIG short welding(2T):
Welding current (peak
current) setting value
Base current setting
value
Press and hold the
welding gun switch
Introduction:
0:Press and hold the gun switch, Electromagnetic gas valve is turned on. The shielding gas starts to flow;
0~t1:
SMART 200 TIG PULSE
Start
current
Loosen the
switch
Striking success
t1
t2
t3
Pre flow time, adjustment range of pre flow time :0~1.0S;
I( A)
Striking
success
5A
t1
t2
0
Pre flow time, adjustment range of pre flow time :0~1.0S;
Repress down the
switch
Loosen the
Crater
switch
current
Stop arc
t4
t5
t6
Loosen the
welding gun
switch
Stop arc
t3
t4
t7
t( s)
t5
t( s)
27