Mounting Methods
Mount to 2-gang U.S. wallbox
Mount to 4 × 4 in (102 × 102 mm), 2.1 in (53 mm) deep
U.S. junction box
Mount to 4 × 4 in (102 × 102 mm), 2.1 in (53 mm) deep
U.S. junction box with barrier
(for 277 V~ loads if required by local electrical code)
Barrier
Mounting Inside Enclosure with
GRAFIK Eye
Control Units
®
• Mount in accordance with all local and national electrical
codes.
• Proper ventilation is required. Ambient temperature inside
enclosure must remain between 32 °F to 104 °F (0 °C to
40 °C) when GRAFIK Eye
are operating.
• See diagram below for required spacing between units.
Note: Plastic faceplate must be installed on module for
normal operation (all models).
GRAFIK Eye
Power
Module
4.5 in (110 mm) minimum
LUTRON
4.5 in (110 mm) minimum
control units and power modules
®
®
LUTRON
LUTRON
LUTRON
LUTRON
LUTRON
Power Modules