6 Putting into operation
6.3.3 Advanced functions
Press buttons (1) and (2) simultaneously to switch to parameter selection mode.
1
Wire retraction/function button
Fig. 8
Advanced functions
Display indicators
Left display (1)
Indicator
Description
F1
Soft start (during operation)
F2
Wire retraction feed rate
F3
Soft start for wire feed
F4
Wire feed rate
F5
Function types of the torch triggers
F6
Power source shut down with
2 and 4-cycle
F7
Special interval function
Tab. 10
Display indicators for advanced functions
Depending on the default settings, the knob (5) can be used to increase or decrease the values.
Fig. 5 Front panel display on page EN-12
EN - 14
1
2
2
Wire feed
Right display (2)
Indicator
Description
Value between
Indicator (4) (bottom) in seconds
Off and 2.0
Wire slowly starts to run
Fig. 5 Front panel display on page EN-12
Value between
Indicator (3) (top) in m/min
0.5 and 3.0
Fig. 5 Front panel display on page EN-12
ON – OFF
Wire slowly starts to run
0.5 – 8.0
Indicator (3) (top) in m/min
Fig. 5 Front panel display on page EN-12
A/b/C
Only possible if the power source should also
be controlled
6.11 Connecting the torch and the welding
device on page EN-25
2 – 4
Optional torch required
ON – OFF
Wire retraction while welding
TIG cold-wire feeder