Cord Sets and Receptacles

Use only high quality, well-insulated, grounded extension
cords with the generator's 120 Volt duplex receptacle.
Inspect extension cords before each use.
Check the ratings of all extension cords before you use
them. Extension cord sets used should be rated for 125 Volt
AC loads at 20 Amps or greater for most electrical devices.
Some devices, however, may not require this type of
extension cord. Check the operator's manuals of those
devices for the manufacturer's recommendations.
Keep extension cords as short as possible to minimize
voltage drop.
WARNING
Overloaded electrical cords can overheat, arc,
and burn resulting in death, bodily injury, and/or
property damage.
• ONLY use cords rated for your loads.
• Follow all safeties on electrical cords.
120/240 Volt AC, 30 Amp, Locking Receptacle
Use a NEMA L14-30 plug with this receptacle. Connect a
4-wire cord set rated for 250 Volt AC loads at 30 Amps (or
greater). You can use the same 4-wire cord if you plan to
run a 120 Volt load.
4-Wire Cord Set
Y (Hot)
NEMA L14-30
This receptacle powers 120/240 Volt AC, 60 Hz, single phase
loads requiring up to 5,000 watts of power (5.0 kW) at
20.8 Amps for 240 Volts or two independent 120 Volt loads
at 20.8 Amps each. The outlet is protected by a double pole
rocker switch circuit breaker.
NOTICE
Receptacles may be marked with rating value greater than
generator output capacity.
• NEVER attempt to power a device requiring more amperage
than generator or receptacle can supply.
• DO NOT overload the generator. See Don't Overload Generator.
240V
120V
120V
W (Neutral)
X (Hot)
Ground (Green)
120 Volt AC, 20 Amp, Duplex Receptacles
Both duplex receptacles are protected against overload by a
double pole rocker switch circuit breaker.
Use each receptacle to operate 120 Volt AC, single-phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at
20 Amps of current. Use cord sets that are rated for 125 Volt
AC loads at 20 Amps (or greater). Inspect cord sets before
each use.

Generator Adapter Cord Set

The generator comes with a 25' generator adapter cord set
designed to provide two sets of 120 Volt, 20 Amp outlets
from one 120 Volt, 20 Amp duplex receptacle.
The maximum load on each outlet is 20 Amps. The
maximum total load on both black wire outlets or white
stripe wire outlets is 20 Amps.
NOTE: Follow all safety precautions when connecting any
extension cord or device to the generator.