Section 4: Operation
the
Engine
(.
Turn OFF and unplug a[( electrical loads from
generator pane( receptacles. NEVER start or stop engine
with electrical devices plugged in and turned ON.
2.
Let engine run at no-load for several minutes to
stabilize internal temperatures
of engine and generaton
3.
Turn engine off according to instructions
given in the
engine operator's
manual.
4.
Move fuel valve to "Off'
position.
REC EPTACLES
CAUTION
•
NEVER
attempt
to power
a device
requiring
more
amperage
than generator or receptacle can supply.
. DO NOT overload the generacon See"Don't Overload
(__enera_or
_',
20/240 Volt AC, 30 Amp,
Locking
Receptacle
Use a NEHA
LI 4-30 plug with this receptacle. Connect a
4-wire
cord set rated for 250VoltAC
loads at 30Amps
(or
greater) (Figure 7).You can use the same 4-wire
cord if you
)lan to run a 120Volt load.
4-Wire
Cord Set
/
\
(Neutral)
IIIIII
NEPIA LI4-30
f-)-7
Ground
(Green)
This receptacle powers
[20/240VoltAC,
60 Hz, single
phase loads requiring up to 7,200 watts of power (7.2 kW)
at 30 Amps for 240Volts or two independent
120Volt
loads at 30 Amps each.The outlet
is protected
by a 30 Amp
rocker switch circuit breaker.
120 Volt
AC,
20 Amp,
Duplex
Receptacles
Each duplex receptacle (Figure 8) is protected
against
overload by a push-to-reset
circuit breaker.
@
Use each receptacle to operate
120VoltAC,
single-phase,
60 Hz electrical
loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).
G EN ERATOR ADAPTER
CORD SET
The generator
is equipped with a 25' generator
adapter
cord set designed for a 240Volt, 30 Amp grounded neutral
circuit (Figure 9).
The maximum load on each outlet is [ 5 Amps.The
maximum total load on both yellow wire outlets or black
wire outlets
is 30 Amps. Each outlet is protected
by a
15 Amp fuse.
NOTE:
Follow all safety precautions
when connecting any
extension
cord or device to the generator.
4@