8. INSTALL TRANSITION TO ROUGH-IN PLATE
(INTERIOR BLOWER ONLY)
Model 423, 424, 427, 453, or 454
Attach transition (if required) to blower
rough-in plate.
Use duct tape to make all joints secure
and air-tight.
NOTE: Model P6 blower plate connects
directly to 7'' round ductwork
without a transition.
9. INSTALL THE ROUGH-IN PLATE TO THE HOOD (ALL BLOWERS)
Run power cable to installation location.
Refer to the instructions included with the
selected blower rough-in plate (sold
separately) for details on installing the
rough-in plate. Attach blower plate to the
studs at the inside, top or back of hood
with (4) no.10-32 nuts, provided. Install
the rough-in plate so that the wiring box
is located on the right side as you are
facing the hood.
For ducting through back of hood,
remove existing plate from inside back of hood and attach it to inside top of hood to cover hole.
Secure to threaded studs with same (4) nuts.
For ducting through top of hood, existing plate remains in place on inside back of hood.
Connect ducting to transition or rough-in plate as you are installing the rough-in plate. Use duct
tape to make all joints secure and air-tight.
10. CONNECT THE WIRING (ALL BLOWERS)
Risk of electrical shock. Electrical wiring must be done by qualified personnel in
accordance with all applicable codes and standards. Before connecting wires, switch
power off at service panel and lock service disconnecting means to prevent power to
be switched on accidentally.
Remove wiring cover from rough-in plate and set aside.
Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground
screw.
Reinstall wiring cover.
HD0049
B
P
LOWER
LATE
HD0048
WARNING
!
- 8 -
N
.10-32
O
NUTS
(2
)
PER SIDE