Install Rough-In Plate; Connect Wiring; Install Blower - Best WPD39M Serie Instrucciones De Instalación

Ocultar thumbs Ver también para WPD39M Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8. INSTALL ROUGH-IN PLATE

Install rough-in plate using 4 x 10-32 locknuts and washers included in hood parts bag. Discard nuts provided with
rough-in plate.
Refer to the instructions included with the selected blower/rough-in kit (sold
separately) for details on installing the rough-in plate. Install the rough-in plate so
that the wiring box is located on the right side as you are facing the hood.
Attach 10" round duct to rough-in plate.

9. CONNECT WIRING

Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power to be switched on accidentally.
Remove wiring cover from rough-in plate and set aside.
Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.
Reinstall wiring cover.
W
ATERPROOF WIRE CONNECTORS INSTRUCTIONS
1. Strip wires 3/8".
2. Align frayed strands or conductors.
3. Do not pre-twist. Place stripped wires together with ends even, but lead smaller stranded wires slightly ahead of larger solid or
stranded wire.
4. Twist connector onto wires pushing firmly until hand-tight. DO NOT over torque.
5. When inserting wires into connectors, some sealant may leak out. Wipe off excess sealant in and around conductors. DO NOT REUSE.

10. INSTALL BLOWER

Refer to instructions included with blower.
Once the blower is installed, plug the blower cord (A) into the female receptacle and the power supply cord (B) onto the male connector
inside the hood.
!
Do not plug the two cords into each other.
:
WARNING
CAUTION
HD0480
WARNING
!
HE0078
8
L
OCKNUTS
A
B

Publicidad

Tabla de contenido
loading

Tabla de contenido