IN CASE OF ANOMALY

13.1

ALARMS

EN
ALARM
CAUSE
AL 1 - BLACK
Power cut during
OUT
ignition phase.
Disconnected fume
temperature probe
AL 2 - FUME
PROBE
Faulty fume
temperature probe
Faulty fume probe
Faulty mother board
AL 3 - HOT
FUME
The exchanger fan
does not work
Too high pellet drop
value
Faulty protection fuse of
the fume fan
AL 4 - FAN
FAILURE
Faulty fume fan
82
Before of every intervention of the Authorized Technician, the same Technician has the
duty to check that the parameters of the mother board correspond with those of the
table you own.
In case of doubts regarding the use of the stove, please call ALWAYS the Authorized
Technician in order to avoid irreparable damages!
SOLUTION
Clean the burning pot and switch the stove on
again.
Have the stove checked.
Replace the fume probe.
Replace the fume probe.
Replace the electronic board.
Replace the ambient fan.
Adjust the pellet loading.
Replace the fuse (1,25A).
The pellets can burn also thanks to the chimney flue
depression and without the aid of the fume fan.
Have the fume fan replaced immediately. It can
be noxious to health to let the stove running without
fume fan.