Mechanical installation
Standard mounting
Mounting steps
5.2.2
Mounting steps
Proceed as follows for the installation:
1. Drill M6 threaded holes in the mounting plate and attach screws and
washers.
–
Four M6 screw and washer assemblies or M6 hexagon socket screws
(property class 8.8) with washers.
–
Attach the screws loosely first.
2. Attach the filter to the prepared mounting plate.
–
Tighten the screws hand−tight.
3. Attach screws and washers to the threaded holes for fastening the
standard device on the filter.
–
Four screw and washer assemblies or hexagon socket screws
M6 x 20 mm with washers.
–
Attach the screws loosely first.
4. Attach the standard device to the filter and tighten the screws fully.
–
Observe the notes given in the documentation for the standard device.
–
Tightening torque: 8 Nm (70.8 lb−in)
5. If necessary, pre−assemble further units.
6. Align all units.
7. Screw all units tightly to the mounting plate.
–
Tightening torque: 10 Nm (88.5 lb−in)