Basic Tool Operation
Before operating the tool check the following:
Inspect tool for damage or leaking oil – do not use tool if it is damaged or leaking oil.
●
Check that correct nosepiece is fitted and tightened to 60 - 65 in-lbs [6.8 – 7.3 N.m] torque.
●
Check that the nose housing nut 10 is tight – hand tighten only.
●
Connect tool to air supply – see air supply requirements (fig.A).
●
Fit Mandrel Collector 11 .
●
Open air supply valve by sliding VA on side of tool
●
(see note below).
Insert rivet into nosepiece.
●
Position rivet in work piece.
●
Pull trigger to set rivet.
●
Release trigger
●
! Note: The Y.135F has an VA (Open-Shut) valve for switching the air supply ON and OFF to save air when the tool is not in use.
Air Supply ON: Open valve
by sliding VA in the
direction shown (up).
VA
FRONT END SERVICE
!! Note: UNPLUG AIR SUPPLY while servicing front-end to avoid INJURY.
NOSE HOUSING NUT
10
NOSE HOUSING
WRENCH FLAT
JAW GUIDE LOCK MOTION
O-RING
PULLING HEAD LOCKING TEETH
JAW GUIDE TEETH
For optimum tool performance, Front-End maintenance should be performed regularly as per the "Preventative Maintenance Schedule".
Dry air
fi g.A
Air Supply OFF: Close Valve
by sliding VA in the
direction shown (down).
JAW GUIDE
PULLING HEAD
JAW GUIDE LOCK
HOUSING ADAPTER
11
12