Technical Data; Operating Conditions; Assembly And Wiring Instructions - Dea 124RR Instrucciones De Uso Y Advertencias

Cuadro de maniobra programable
Ocultar thumbs Ver también para 124RR:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Operating instructions and warnings
WARNING DEA System reminds all users that the selection, positioning and installation of all ma-
terials and devices which make up the complete automation system, must comply with the European
Directives 2006/42/CE (Machinery Directive), 2004/108/CE (electromagnetic compatibility), 2006/95/
CE (low voltage electrical equipment). In order to ensure a suitable level of safety, besides complying
with local regulations, it is advisable to comply also with the above mentioned Directives in all non-
European countries.

5 TECHNICAL DATA

Power supply
Flashing light output
Auxiliary power supply output (+24VAUX)
Safety devices power supply output (+24VSIC)
LC/SCA contact capacity LC/SCA
Max motor capacity
Fuse F1 (retarded)
Fuse F2 (retarded)
Radio receiver frequency
Max. number of transmitter controlled

6 OPERATING CONDITIONS

124RR control board is designed for the automation of DEA System gates operators in 24V
therefore it is fit for overhead doors, sliding gates and barriers.
This control board is designed and tested for operation under "normal" conditions for both residential
and industrial use. The level of protection against dust and water and other data are illustrated in the
instructions booklet of each gate operator DEA System, equipped with the 124RR control board.
WARNING Using the product under unusual conditions not foreseen by the manufacturer may
cause dangerous situations; this is the reason why all the conditions prescribed in these instructions must
be followed.
WARNING Under no circumstance must the product be used in an explosive environment or sur-
roundings that may prove corrosive and damage parts of the product.
7
WARNING To ensure an appropriate level of electrical safety always keep the 230V cables (power
supply) apart from low voltage cables (motors power supply, controls, aerial and auxiliary circuits
16
power supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING Any installation, maintenance or repair operation on the whole system must be carried
out exclusively by qualified personnel. All these operations must be performed only after disconnecting
the power supply, and operating in strict compliance with the electrical standards and regulations in
force in the nation of installation.
WARNING Install and wire the control board according to the instructions given in the instruction
booklet of each gate operator DEA System (such as hole drilling to allow for wires passage, use of wire
clamps, etc.)
Failure to comply with these instructions may jeopardize the level of electrical safety.
Connect to the power supply 230 V ~ ± 10% 50 Hz through a multi pole switch or a different device
that can ensure multi pole disconnection from the power supply, with a contact opening of 3,5 mm. Use
a cable with a minimum section of 3 x 1,5 mm² (e.g. a H07RN-F type).
Make all connections to the terminal board and remember to short-circuit, whenever necessary, all
unused inputs. (See table 1 terminal board connection and wiring diagram)
124RRC
124RRCB

ASSEMBLY AND WIRING INSTRUCTIONS

124RR
(905/24RR,
(3/24RR, 6/24RR)
1000/24, 1001/24)
230 V ~ +/- 10% 50Hz
30 V
max 10W art. Lumy 24S
24 V
24 V
max 5A - 24V
150W
150W
T2A
T2A
T15A
T15A
433,92 MHz rolling code / dipswitch coding
124RRS
124RR
124RR
(
(PASS/24)
10/24RRS)
(max 200mA)
(max 200mA)
80W
80W
250W
T1A
T2A
T2A
T15A
T15A
T15A
100
A1
, and
A2
A3
A5
A6

Publicidad

Tabla de contenido
loading

Tabla de contenido