6. Technical data

Type
Input data
Rated control supply voltage U
Control supply voltage range
Control supply voltage
Rated control supply current as per IEC 60947-1
Control input ON:
Output data
Circuit principle
Rated operating voltage U
Operating voltage range
Load current at 20°C (see 8.2. Derating curve)
Load current at 20°C without safety function and
asymmetry recognition (see 8.2. Derating curve)
Rated operating current I
AC-51
AC-53a
Nominal switching performance
Leakage current (input, output)
Residual voltage at I
e
Surge current
Input protective circuit
Short circuit current rating SCCR
Order No. ELR H3-IES-SC- 24DC/500AC-0,6 2900566
s
as per IEC 60947-1 / UL 508
Switching level "Safe off" < 5 V DC
Switching level "Low" -3 ... 9.6 V DC
Switching level "Safe off" < 5 V DC
Switching level "High" 19.2 ... 30 V DC
Input current ≤ 5 mA
load side ELR...-0.6
as per IEC 60947-1 500 V AC (50/60 Hz)
e
as per IEC 60947-1
as per UL 508
as per IEC 60947-1
e
as per IEC 60947-4-3
as per IEC 60947-4-2
as per UL 508
as per UL 508
Full Load (power factor = 0.4)
Full Load (power factor = 0.8)
acc. to UL 508 - suitable for use on a circuit capable of delive-
ELR H3-IES-SC- 24DC/500AC-2
ELR H3-IES-SC- 24DC/500AC-9
ELR H3-IES-SC-230AC/500AC-0,6 2900689
ELR H3-IES-SC-230AC/500AC-2
ELR H3-IES-SC-230AC/500AC-9
ELR...-24DC/...
24 V DC
19.2 ... 30 V DC
(32 V DC, max. 1 min.)
≤ 40 mA
ELR...-2
Safety end level with bypass, three-phase
electrically isolated switch-off
42...550 V AC
42...500 V AC
0.075...0.6 A
0.18...2.4 A
0... 0.6 A
0...2.4 A
0.6 A
2.4 A
0.6 A
2.4 A
0.6 A
2.4 A
0.3 kW (0.4 HP)
0.9 kW (1.2 HP)
0.5 kW (0.6 HP)
1.7 kW (2.2 HP)
0 mA
0 mA
< 300 mV
< 300 mV
100 A (t = 10 ms)
Varistors
ring not more than 5 kA
500 V maximum
- suitable for use on a circuit capable of delive-
ring not more than 100 kA
peres, 500 V maximum when protected by a
30 A class J or CC fuse
2900567
2900569
2900568
2900570
ELR...-230AC/...
230 V AC (50/60 Hz)
85 ... 253 V AC
< 5 V AC
≤ 4 mA
< 44 V AC
< 5 V AC
85 ... 253 V AC
≤ 7 mA
ELR...-9
1.2... 9.0 A
0...9.0 A
9 A
6.5 A
6.5 A
2.3 kW (3.0 HP)
4.6 kW (6.1 HP)
0 mA
< 500 mV
symmetrical amperes,
rms
symmetrical am-
rms
19