Installation and Operating Data
Maximum Overcurrent Protection - 15A
Use Copper Conductors Only
Disconnect Power before Opening Service Cover
For Outdoor or Indoor Use
Electrical Requirements: 120/240 VAC 50/60 Hz 3
WIRE, 1.3 AMP
Maximum Output of Hypochlorous Acid is Equivalent to 420 g
of Free Available Chlorine Per Day
4,000 parts per million of salt
The maximum volume of water that can be treated with
one unit of APURE35/APURE35C is 132,000 litres
(35,000 gallons) (132.0 m
For swimming pools, a range of 1-3 ppm of available
chlorine must be maintained.
Controls bacteria and algae in swimming pool water.
BUILDER/INSTALLER: Please leave this manual with the pool owner.
POOL OWNER: Please save this manual.
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is
licensed and qualified in pool equipment by the jurisdiction in which the product will be
installed where such state or local requirements exists. In the event no such state or local
requirement exists, the installer or maintainer must be a professional with sufficient experience
in pool equipment installation and maintenance so that all of the instructions in this manual
can be followed exactly. Before installing this product, read and follow all warning notices and
instructions that accompany this product. Failure to follow warning notices and instructions
may result in property damage, personal injury, or death. Improper installation and/or operation
will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can cause
serious injury, property damage, or death.
Operating AquaPure models APURE35 and APURE35C without water fl ow through the cell can
cause a buildup of fl ammable gases which can result in FIRE OR EXPLOSION.
KEEP OUT OF REACH OF CHILDREN
AquaPure
by Zodiac Pool Systems, Inc.
6000 Condor Drive
Moorpark, California, 93021 USA
In US: (800) 822-7933 • In Canada (888) 647-4004
www.jandy.com
APURE35 and APURE35C
Chlorine Generating Device
For Residential Pools
PEST CONTROL PRODUCTS ACT
Installation and Operation Manual
)
3
WARN ING
Domestic
TM
Series