3.6 Connection to an AquaLink
The Jandy
AquaLink RS or PDA is a multi-function pool controller which can fully control the function of the Jandy
®
AquaPure
Ei
chlorine generating device. Adjustment of the chlorine production rate can be controlled from the
®
TM
main menu of the Jandy AquaLink RS or PDA. The AquaLink RS or PDA offers individual pool and spa settings for
output percentage. Refer to the AquaLink RS or PDA Owner's Manual for more information.
NOTE The Jandy AquaPure Ei chlorine generating device will communicate with all AquaLink models Rev. K or later.
3.6.1 Verify the Controller Type on the Power Pack is Set Correctly
Before wiring to an AquaLink RS Control System, the controller type must be set to JANDY L/M to allow
communication between the power pack and the AquaLink RS Control System. The default controller type setting on
the power pack is Jandy L/M. Follow the instructions below to verify the controller type is set correctly.
NOTE The controller type must be set correctly before making the wiring connection between the power pack and
the AquaLink, otherwise the power pack may be locked out of the AquaLink.
To verify the controller type is set correctly:
1. Apply power to the power pack.
2. Wait for the start-up sequence to complete.
3. Press and hold the OUTPUT button for approximately four (4) seconds. After four (4) seconds, a controller type
will be displayed on the screen.
4. Verify that the JANDY L/M controller type appears on the display. If the contoller type is not set to JANDY L/M,
keep the OUTPUT button pressed to toggle through the list of contollers. Each controller will be displayed on the
screen for two (2) seconds. Release the OUTPUT button when JANDY L/M appears on the display.
3.6.2 Wiring to the AquaLink RS Control System or PDA
FOR YOUR SAFETY: This product must be installed and serviced by a professional pool/spa service
technician as described on the front cover of this manual. The procedures in this manual must be followed
exactly. Failure to follow warning notices and instructions may result in property damage, serious injury, or death.
Improper installation and/or operation will void the warranty.
When using electrical products, basic precautions should always be followed, including the following:
•
DANGER: RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. Before
attempting installation or service, ensure that all power to the device is disconnected/turned off at the circuit
breaker. Connect only to a circuit protected by a ground-fault circuit-interrupter (GFCI).
•
Grounding is required. The unit should be serviced by a qualifi ed service representative and should be properly
grounded. (See Section 3.4, Wiring the Power Pack to Power Source).
•
Install to permit access for servicing.
•
Please read all cautions and safety instructions in the Important Safety Instructions section. Before attempting
any electrical wiring, be sure to read and follow safety instructions. Wiring should only be attempted by
a qualifi ed professional.
1. Ensure that all power to the power pack and the controller is disconnected/turned off at the circuit breaker.
2. Remove the screws attaching the cover to the back plate and prop the cover up to expose the terminals
(see Figure 19).
NOTE Be careful not to pull the ribbon cable that is connected to the Power Supply and the Cover.
RS Control System or PDA (Optional)
®
WARNING