Page 8
Section 2.
System Description
Heater
Cell
The cell must be installed as the
last piece of equipment in the
circulation plumbing system just
before the pool
Figure 1.
Example of Installation
2.1 Product Specifi cations (APURE35 and APURE35C)
Maximum Operating Pressure: 50 psi
Minimum Flow Rate: 152 lpm (40 gpm)
Maximum Flow Rate: 348 lpm (92 gpm)
Required Salt Level: 4,000 ppm (4.0 gpl)
Maximum water volume treated:
132,000 L (35,000 gal.)
Chlorine Output:
0.42 kg (0.93 lbs.) per day
Input Voltages: 240 V or 120 V (the system
auto-detects voltage)
Input Current @ 240 VAC: ~1 A
Input Current @ 120 VAC: ~1.3 A
Pool Return
Input Freq: 47~63 Hz
Output Voltage: 25V DC (max)
Output Current: 5A DC
Dimensions:
Power Pack (L x W x H):
25.4 cm x 11.4 cm x 33 cm (10 in. x 4.5 in. x 13 in.)
Electrolytic Cell (L x W x H):
16.5 cm x 14 cm x 30.5 cm (6.5 in. x 5.5 in. x 12 in.)
Weight:
Power Pack: 3.2 kg. (7 lbs)
Electrolytic Cell: 0.9 kg (2 lbs.)
Power Pack
Filter
Pool Intake
Spa Return
To common
power source
Pump
Spa Intake