These adjustments are stored in memory and automatically
recalled when the display receives the same input signal.
S C R E E N
P H A S E
P I T C H
H C E N T E R
V C E N T E R
A U T O
O N
1 2 8 0
x Adjust the picture's sharpness manually
(PHASE/PITCH)
You can adjust the picture's sharpness as follows. This
adjustment is effective when the computer is connected to the
monitor's HD15 input connector (analog RGB).
1 Set the resolution to 1280 × 1024 on the computer.
2 Load the Utility Disk.
3 Start the Utility Disk and display the test pattern.
For Windows
Click [Utility]
[Windows]/[Win Utility.exe].
t
For Macintosh
Click [Utility]
[Mac]/[Mac Utility].
t
4 Press the MENU button.
The main menu appears on the screen.
5 Press the M/m buttons to select
press the OK button.
The SCREEN menu appears on the screen.
6 Press the M/m buttons to select PHASE and press
the OK button.
The PHASE menu appears on the screen.
7 Press the M/m buttons until the horizontal stripes
are at a minimum.
Adjust so that the horizontal stripes are at a minimum.
8 Press the OK button.
The main menu appears on the screen.
If vertical stripes are observed over the entire screen, adjust
pitch by the following steps.
9 Press the M/m buttons to select
press the OK button.
The SCREEN menu appears on the screen.
10 Press the M/m buttons to select PITCH and press the
OK button.
The PITCH menu appears on the screen.
x
1 0 2 4
/
6 0 H z
E X I T
(SCREEN) and
(SCREEN) and
11 Press the M/m buttons until the vertical stripes
disappear.
Adjust so that the vertical stripes disappear.
12 Click [END] on the screen to turn off the test pattern.
13 Press the M/m buttons to select
button.
Return to the menu screen.
x Adjust the picture's position manually
(H CENTER/V CENTER)
If the picture is not in the center of the screen, adjust the picture's
centering as follows.
1 Set the resolution to 1280 × 1024 on the computer.
2 Load the Utility Disk.
3 Start the Utility Disk and display the test pattern.
For Windows
Click [Utility]
t
[Windows]/[Win Utility.exe].
For Macintosh
Click [Utility]
[Mac]/[Mac Utility].
t
4 Press the MENU button.
The main menu appears on the screen.
5 Press the M/m buttons to select
press the OK button.
The SCREEN menu appears on the screen.
6 Press the M/m buttons to select H CENTER or
V CENTER and press the OK button.
The H CENTER or V CENTER menu appears on the screen.
7 Press the M/m buttons to center the test pattern in
the screen.
8 Click [END] on the screen to turn off the test pattern.
9 Press the M/m buttons to select
button.
Return to the menu screen.
and press the OK
GB
(SCREEN) and
and press the OK
13

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido