5. Troubleshooting

I do not hear a dial tone.
• Check that all the cords and plugs are connected correctly.
• Check that the power adapter is plugged in and has power.
• Check that the on-line indicator is lit. If it is not, place the headset in the base unit and take it out again.
• Check that the battery is charged. If the battery is fully charged, the battery charging indicator on the
base unit will light when the headset is placed correctly in the base unit.
The person I am talking to has dif culties hearing me.
• Check that the mute function is o .
• Check the position of the boom arm and make sure that the microphone is placed as close as possible
to your mouth.
• Readjust the microphone volume.
• You may be out of range of the headset's base unit. Move closer to the base unit.
My battery charging light keeps ashing and will not go solid.
Check the battery is correctly tted inside the headset, and/or the headset is placed correctly in the
base
I have set up my GN9120 correctly, but I am getting a buzzing sound on my headset.
Your telephone may not be fully immune to the radio transmission between your headset and base. To
overcome this problem, move the base at least 30 cm/12" away from the phone. If you have a European
version, you can instead choose to set the headset to Low Power mode.
The person on the other end of the line says he/she cannot hear me.
Ensure that the Telephone Termination Switch is in the correct position and that you have adjusted the
Transmit Power. Please refer to the relevant section in the reference guide.
When I press the MFB the GN 1000 RHL lifts but the call is not connected.
When using your GN 9120 with a GN 1000 RHL, make sure that the base is connected to the telephone's
handset port and not the headset port. Please refer to the illustrations in the GN 1000 RHL Quick Guide
My headset echoes.
Make sure your telephone's volume control is set to a mid position or lower. If necessary, adjust your
microphone volume on the headset to a lower setting
I have a GN 9120-xx-1x, the version with built-in Electronic Hook Switch, but it doesn't work
with my telephone
Please make sure that the GN 9120 is compatible with your telephone system, and set the GN 9120 in
the correct mode. For standard telephones and for use with GN 1000 RHL, please make sure to put the
GN 9120 in RHL mode.
My headset was working but now it has stopped, no indicators are lit.
Your headset may need pairing to the base. Refer to page 7 "Registering a new master headset" in this
reference guide.
Please call
1-800-923-0018 extension 405
6
Repro_GN 9120_RefG_Content.indd 6
for further information and frequently asked questions.