Installation and connection

Set-up the unit
• Install the unit flood protected in a horizontal position.
Ensure that the unit is installed with a safety distance of at least 2 m from the water.
• Install the unit above the level of the water, otherwise it will be damaged by water flowing back.
Damage resulting from incorrect installation is not basis for a claim within the framework of the guarantee or warranty.
Connect the unit
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the
units and installations (switch off and disconnect from the power supply) before reaching into the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
• Keep the air hose as short as possible and lay it well protected.
• Connect the aeration stone to the air hose and position the aeration stone in the pond.
• Attach the free end of the air hose to the air outlet on the unit.
Commissioning/start-up
Switching on the unit: Plug the power plug of the transformer into the socket. The unit switches on immediately.
Switching off the unit: Disconnect the transformer power plug.

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the
units and installations (switch off and disconnect from the power supply) before reaching into the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
• Should the performance reduce, clean the air intake opening in the base of the housing.
Replacing the membranes
Note!
• Never operate the unit with defective membranes.
• Always replace both membranes even when only one membrane is defective. The procedure is identical
for both membranes.
• Please contact your specialist dealer if you do not wish to undertake the replacement yourself.
• Remove the hood by unscrewing the screws from the unit underside (A).
• Disconnect the connection hose from the pump heads (B) on the left-hand and right-hand side.
• Lift the motor block (C) and remove the diaphragm chamber (D) fitted with four screws.
• The membrane can be replaced after loosening the screw and removing the support disk (E). Ensure correct insertion
(note the shape).
• Reassemble the unit in the reverse order and put it back into operation.