- EN -
9
Operation
9.1
Controller overview
Displays on the controller
The display (C1) shows
− the water temperature as standard.
− automatically the water temperature again 2 seconds after the last key operation.
− the cleaning programs if selected accordingly.
− the saved settings when pressing a key.
− the remaining operating life (h × 100) of the UVC lamp.
Displayed messages (C1)
− "LA" flashes in an 8 sec. interval 1×: The UVC lamp was active for 7500 operating hours; remaining operating life: 500
operating hours
− "LA" flashes in an 8 sec. interval 2×: The UVC lamp has operated for 8000 hours and should be replaced.
− "PS" lights up in a 4 sec. interval: The dirty water pump has reached its max. running time and is blocked for 1.5 hours.
LED for dirty water pump (C2)
− LED flashes green: Partial container drainage.
− LED is lit green: complete container drainage.
− LED is lit red: Pump blocked.
− LED off: Pump not active.
LED for UVC clarifying unit (C3)
− LED is lit blue: UVC clarifying unit is switched on.
− The LED flashes in an 8 sec. interval blue: The UVC clarifying unit is integrated in the Automatic (AU) operating program.
− LED off: UVC clarifying unit is switched off.
Note:
The integrated thermometer permanently measures the water temperature, thereby forming the reference value for the operating
programs.
The silicone cover protects the controller from soiling; it impairs neither the display reading nor the functionality of the keys. The
controller is water tight and can also be operated without the silicone cover.
30
C1
Display
C2
LED displaying the dirty water
pump function
C3
LED displaying the UVC
function
C4
Key for manual dirty water
pump operation
C5
Key for setting a cleaning
program for the dirty water
pump
C6
Key for setting an operating
program for the UVC clarifying
unit