3. Align mounting holes and install 4 - 6 x 16 mm screws.
B
A. Screw with lock washer
B. Mounting hole
4. Attach power cord connector to connector on wire box on blower
motor mounting plate.

Make Electrical Connection

WARNING: Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Locate junction box of the range hood.
3. Remove terminal box cover and set aside.
A. Knockout in canopy back into terminal box
4. Remove knockout from terminal box and install a UL
listed or CSA approved ½" strain relief.
5. Place the range hood near its mounting position and run the
power supply cable through the strain relief into terminal box
(enough to make connection).
A
6. Tighten the strain relief screws.
B
A
A.White wires
B. Black wires
C. UL listed wire connectors
7. Use UL listed wire connectors and connect black wires (B)
together.
8. Use UL listed wire connectors and connect white wires (A)
together.
9. Connect green (or bare) ground wire from home power supply
to the green/yellow ground wire (D) in terminal box using UL
listed wire connectors.
10. Install terminal box cover.
11. Check that all light bulbs are secure in their sockets.
12. Reconnect power.

Complete Installation

Secure the 8" (20.3 cm) round vent transition with damper to top
of the range hood using 2 - 3.5 x 9.5 mm screws.
Attach the upper duct covers using 6 - 3.5x6.5 mm screws.
9
E
F
C
D
D. Green, Bare or Yellow/Green wires
E. Home power supply
F. UL listed or CSA approved ½" strain
relief