Direct Wire Connection - Kenmore 191.57754412 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DIRECT WIRE CONNECTION

Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected
to green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, re, or
electrical shock.
Direct Wire Strain Relief
1.
Attach direct wire strain relief
A
B
C
Unscrew the removable conduit connector (A) and any
screws from a 3/4" (19 mm) UL Listed strain relief. Put the
threaded section of the strain relief (C) through the hole below
the terminal block opening (B). Reaching inside the terminal
block opening, screw the removable conduit connector (A)
onto the strain relief threads.
Fire Hazard
2.
Attach direct wire cable to strain relief
Put direct wire cable through the strain relief. The strain relief
should have a tight fi t with the dryer cabinet and be in a
vertical position. Tighten strain relief screw against the direct
wire cable.
If your wiring looks like this:
4-wire direct connection:
Go to "4-Wire Direct Connection"
on this page.
3-wire direct connection:
Go to "3-Wire Direct Connection."
4-Wire Direct Wire Connection
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit 3-wire connections.
1.
Prepare your 4-wire cable
for direct connection
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,
leaving bare ground wire at 5" (127 mm). Cut 1½" (38 mm)
from remaining three wires. Strip insulation back 1" (25 mm).
Shape ends of wires into hooks.
13

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido