3.
Connect neutral wire
C
Place hooked end of neutral wire (white
or center) (C) of direct wire cable under
center terminal block screw (B). Squeeze
hooked end together. Tighten screw.
4.
Connect remaining wires
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tabs of terminal block cover into slots of dryer rear
panel. Secure cover with hold-down screws. Now, go to
"Venting Requirements."

Optional 3-Wire Connection

You must verify with a qualified electrician that this
grounding method is acceptable before connecting.
1.
Prepare to connect neutral
ground wire and neutral wire
E
Remove center terminal block screw (B). Remove neutral ground
wire (E) from external ground conductor screw (A).
2.
Connect neutral ground wire
and neutral wire
B
C
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
3.
Connect remaining wires
Connect remaining wires to outer terminal block screws.
Tighten screws.
4.
Connect external ground wire
G
B
Connect a separate copper ground wire (G) from the external
ground conductor screw (A) to an adequate ground. Finally,
reinsert tabs of terminal block cover into slots of dryer rear
panel. Secure cover with hold-down screws. Now, go to
"Venting Requirements."
A
E
B
A