Technical data

Ref. no.:
Compressor cooling capacity:
Cooling capacity based on ISO 5151:
Rated input voltage:
Power consumption in cooling mode:
Required fuse:
Operating temperature range:
Refrigerant:
Refrigerant quantity:
CO
equivalent:
2
Global warming potential (GWP):
Blower:
Protection class:
Max. volume of space in the vehicle
(with insulated walls):
Dimensions L x W x H,
fig. 7, page 5:
Weight:
Inspection/certification:
Contains fluorinated greenhouse gases
Hermetically sealed equipment
EN
Technical data
FreshJet1500E
9105306669
1500 W
1500 W
230 Vw/ 50 Hz
2.7 A
4 A
0 °C to +52 °C
R-410a
0.54 kg
1.12752 t
2088
2 blower levels
IPX4
20 m³
787 x 562 x 225 mm
(height above vehicle roof)
approx. 28 kg