Connecting The Hob To The Mains Power Supply - EAS ELECTRIC EMIH280-3F Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9.6 Cautions
1. The induction hotplate must be installed by qualified personnel or technicians. We have
professionals at your service. Please never conduct the operation by yourself.
2. The hob will not be installed directly above a dishwasher, fridge, freezer, washing machine
or clothes dryer, as the humidity may damage the hob electronics
3. The induction hotplate shall be installed such that better heat radiation can be ensured to
enhance its reliability.
4. The wall and induced heating zone above the table surface shall withstand heat.
5. To avoid any damage, the sandwich layer and adhesive must be resistant to heat.
6. A steam cleaner is not to be used.

9.7 Connecting the hob to the mains power supply

This hob must be connected to the mains power supply only by a suitably qualified
person. Before connecting the hob to the mains power supply, check that:
1. The domestic wiring system is suitable for the power drawn by the hob.
2. The voltage corresponds to the value given in the rating plate
3. The power supply cable sections can withstand the load specified on the rating plate. To
connect the hob to the mains power supply, do not use adapters, reducers, or branching
devices, as they can cause overheating and fire. The power supply cable must not touch any
hot parts and must be positioned so that its temperature will not exceed 75˚C at any point.
Check with an electrician whether the domestic wiring system is suitable without
alterations. Any alterations must only be made by a qualified electrician.
If the total number of heating unit of the appliance you choose is not less than 4, the
appliance can be connected directly to the mains by single-phase electric connection, as
shown below.
If the cable is damaged or to be replaced, the operation must be carried out the by after-sale
agent with dedicated tools to avoid any accidents.
If the appliance is being connected directly to the mains an omnipolar circuit-breaker must
be installed with a minimum opening of 3mm between contacts.
Yellow / Green
5
Black
4
L1
Brown
L2
3
2
N1
Blue
N2
1
N2
1
24
Yellow / Green
5
Black
L1
4
Brown
L2
3
2
N1
Blue
V.3