11. The unit will dispense the descaling solution at intervals of around 10 minutes
during the first stage. During this stage, the red and orange indicator lights will blink
alternately. There is no need to press the button during each interval, just wait.
12. If container fills up, empty it out.
13. When the cycle of the first stage is over, the blue light of the middle "Double
Espresso" button and the malfunction red and orange indicator lights will start
blinking alternately again.
NOTE: THE FIRST STAGE OF DESCALING LASTS AROUND 40 MINUTES.
RINSE CYCLE – SECOND STAGE
1. Carefully hand wash and rinse out the water tank and fill it with approximately
0.7 liters of fresh drinking water.
2. Empty and rinse out the used capsule drawer and drip tray.
3. Press the Power button to turn unit off "O".
4. Make sure there are no capsules in the capsule compartment.
5. Make sure the lever is lowered.
6. Remove and empty out the water tank.
7. keep the three brew buttons pressed down and while holding them down press
the power button to turn unit on "I".
1. Press the power button to turn unit off "O"
2. Make sure there are no capsules in the capsule compartment.
3. Make sure the lever is lowered.
4. Remove and empty out the water tank.
5. keep the three brew buttons pressed down and while holding them down press
the power button to turn unit on "I".
6. The indicator light will blink and the unit will carry out a drainage cycle. At the
end of the process, the unit will emit a beep sound.
7. Turn the unit off.
IMPORTANT: THE NExT TIME yOU TURN IT ON; yOU WILLHAvE TO CARRy
OUT A NEW START-UP PROCEDURE.