Cebora PLASMA SOUND PC 70/T Manual De Instrucciones página 23

Ocultar thumbs Ver también para PLASMA SOUND PC 70/T:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 64
2.2 EXPLANATION OF THE TECHNICAL SPECIFICA-
TIONS LISTED ON THE MACHINE PLATE.
The equipment is manufactured according to these
international standards:IEC 60974-1, IEC 60974-7, IEC
60974-10 Cl. A, IEC 61000-3-11, IEC 61000-3-12 (See
note 2).
ART. 334
Duty Cycle (X)
Conventional cutting current (I2)
Conventional load voltage (U2)
Rated no-load voltage (Uo)
IEC 60974-1 *
Rated supply voltage (U1)
Rated maximum supply current (I1max)
Effective maximum supply current (I1eff)
Cutting current (I2)
CEBORA
CP 162C**
Effective maximum supply current
CP 70C**
(I1 eff max)
Degree of housing protection
ART. 336
Duty Cycle (X)
Conventional cutting current (I2)
Conventional load voltage (U2)
Rated no-load voltage (Uo)
IEC 60974-1 *
Rated supply voltage (U1)
Rated maximum supply current (I1max)
Effective maximum supply current (I1eff)
Cutting current (I2)
CEBORA
CP 162C**
Effective maximum supply current
CP 70C**
(I1 eff max)
Degree of housing protection
* Machine data measured in accordance with standard IEC60974-1
** Machine data measured under actual cutting conditions with torch CP162C / CP70C
35%
60%
100%
70 A
60 A
50 A
108 V
104 V
100 V
278/292/305 V
3 ~ 50/60 Hz
208 V
220 V
230 V
25 A
24 A
23 A
17 A
15 A
13 A
21 A
IP23S
35%
60%
100%
80 A
65 A
60 A
112 V
106 V
104 V
280/296/310 V
3 ~ 50/60 Hz
208 V
220 V
230 V
29 A
27 A
26 A
20 A
19 A
18 A
80 A
30 A
IP23S
60%
100%
70 A
60 A
108 V
104 V
263/288 V
400 V
440 V
14 A
12 A
11 A
10 A
70 A
14 A
50%
60%
100%
110 A
95 A
90 A
124 V
118 V
116 V
277/305 V
400 V
440 V
23 A
21 A
17 A
16 A
110 A
23 A
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Plasma sound pc 110/tPlasma sound pc 130/t334336337

Tabla de contenido