18. INSTALL THE BLOWER (INTERIOR BLOWER)
Install (4) no. 8 x 3/8'' screws into the location as shown in the pictures below (single blower or dual blower). Do not
tighten screws down fully, leave a 1/8" gap. Hang blower unit onto blower plate (screws through the large part of the
keyhole). Slide the blower to its position (screws in the small part of the keyhole). Tighten the (4) screws.
HD0044
Single blower (P5)
Secure the blower by installing 2 more no. 8 x 3/8'' screws for the P5 blower and 4 more no. 8 x 3/8'' screws for P8 into
the locations shown in the pictures below (single blower or dual blower). Reinstall impeller(s) and cover.
HD0080
Single blower (P5)
FOR DUAL BLOWER UNIT, MAKE SURE
THE IMPELLERS ARE CORRECTLY
INSTALLED, THE INSERT WILL NOT
WORK PROPERLY IF REVERSED. Both
impellers are different in the dual blower,
one rotates clockwise and the other
counterclockwise. Each wheel and motor
have an arrow and a number on them, you
have to match them correctly (see drawing
beside).
Never plug the 2-prong blower cord to the 3-prong power supply cord.
Plug the power supply to the 3-prong male connector (A) and the blower
unit into the 2-prong female receptacle (B) inside the insert.
HD0045
Dual blower (P8)
HD0081
Dual blower (P8)
1
HD0023
WARNING
!
- 11 -
(CONT'D)
FRONT
A
B
HE0022
2